FPFF-L3.2

Fixed fire-extinguishing systems

FPFF-M3 · Equipment · FPFF-M3-A Extinguishing agents and portable extinguishers, fixed systems, and firefighting equipment and outfits.

Engine rooms, garages and galleys on yachts are protected by **fixed systems**. What they are, how they are released, and the dangers.

Fixed installations

Governing: STCW Table A-VI/1-2 ("instruction in fixed installations"); REG Yacht Code Part A, 15A.7 and Table 15A.1; MGN 681 (M) Amendment 1, section 8. Builds on: L3.1.

Portable extinguishers deal with small fires. Spaces where a fire would grow too fast or burn too hot to fight by hand are protected by fixed systems. As a basic training candidate you will not design or maintain them, but you must know what they are, where they are, and what happens when they operate.

Where fixed systems are required

REG Yacht Code Table 15A.1 requires, for every Category A machinery space, a fixed fire-extinguishing system approved under the Fire Safety Systems (FSS) Code. A machinery space with an oil-fired boiler or oil fuel unit needs one too (15A.7). Larger yachts, Chapter 14.1 garages and battery stowage have further requirements.

Types

System How it works Typical yacht use Key hazard
CO2 total flooding Floods the space, reducing oxygen Engine rooms, older yachts Lethal to anyone inside
Clean agents (chemical gases) Chemical and physical action on the flame Engine rooms, technical spaces Decomposition products; oxygen reduction varies
Water mist Very fine droplets absorb heat and displace oxygen locally Engine rooms, garages, accommodation Electrical equipment exposure
Sprinklers Heat-activated heads spray water Accommodation on larger yachts Water damage
Galley hood systems Wet chemical discharged into the hood and duct Galley ranges and fryers Must be manually activated if detection fails
Local application Water mist or gas aimed at a specific hazard Generators, purifiers –

Older yachts may still have systems using agents now phased out; the SMS will say.

Releasing a gas system

Release is a command decision. The usual sequence:

  1. Evacuate the space and complete a head count.
  2. Stop ventilation and close fire dampers.
  3. Stop fuel: quick-closing valves, fuel pumps.
  4. Close all doors, hatches and skylights.
  5. Release from the protected release station, following the posted instructions.
  6. Keep boundaries cool and monitor temperatures.
  7. Wait. Opening the space too soon re-admits air and can re-ignite the fire.

Pre-discharge alarms sound in the space before a gas system releases. If you hear one, get out immediately.

WARNING — Never re-enter without authority After a gas release the atmosphere may be lethal. Re-entry is ordered by the master, made with breathing apparatus, after ventilation and testing. MGN 681 requires portable atmosphere testing instruments aboard.

Water mist

Water mist is increasingly common on yachts. It cools strongly, uses little water, and is generally safer for people than gas flooding. MGN 681 notes that water-mist systems have been shown to be the most effective solution for battery-fire suppression and recommends automatic water-based systems in battery compartments.

Your role

  • Know which spaces on your yacht have fixed systems and where the release stations are.
  • Know the pre-discharge alarm.
  • Never obstruct nozzles, detectors or release points with stowed gear.
  • Report any accidental damage to pipework or heads.

CAUTION — Accidental release Refit work near CO2 cylinders or release cables has caused accidental discharges. Treat release stations as off limits unless you are trained and ordered.

Practice questions

5 questions

recall · core

What does REG YC Table 15A.1 require in a Category A machinery space? (a) Only portable extinguishers (b) A fixed fire-extinguishing system approved under the FSS Code plus portables (c) A sprinkler system only (d) A fire blanket

recall · core

What must happen before a CO2 total flooding system is released into an engine room? (a) Open the skylights (b) Start the fire pump (c) Nothing; it is automatic (d) Evacuate and count all persons, stop ventilation and fuel, close openings

recall · core

Why is CO2 total flooding dangerous to people? (a) It is flammable (b) It freezes the deck (c) It is corrosive (d) It displaces oxygen in the space

recall · core

Which fixed system does MGN 681 describe as most effective for battery fires? (a) CO2 (b) Dry powder (c) Water mist (d) Halon

scenario · core

Engine room fire on a 48 m yacht. The chief engineer is preparing to release the fixed system. The second engineer is missing. What happens? (a) Release immediately to save the vessel (b) The master decides, with the head count confirmed; release is delayed while the missing person is accounted for if it is safe to do so (c) The chief engineer decides alone (d) Wait for the fire to go out

Independent study. xplor is not an accredited training provider and awards no certificate or Certificate of Competency. The FPFF certificate of proficiency requires live fire, smoke and breathing apparatus exercises at an MCA-approved (or flag-recognised) training centre, and its five-yearly update cannot be earned on board. AI-drafted content pending subject-matter-expert review.